Devices
Jetibox
CEX can simulate a Jetibox to read telemetry from legacy Jeti devices.
- Enable: It can be enabled or disabled by the user.
- SCI Port: A SCI port must be selected. The available options are: SCI A, SCI B or SCI C.
Besides, a configuration is needed in the Serial and I/O Setup panels.
An example of this can be seen in the Jetibox - Integration examples section of the present manual.
Note
The serial port will be totally reserved for this, so it will not be usable to other things and the I/O Setup affecting it wil be ignored.
Scorpion tribunus
CEX can read telemetry from Tribunus ESCs by connecting it to one of its serial ports.
The following parameters are configurable:
- Enable: It can be enabled or disabled by the user.
- Telemetry period.
- MCU telemetry 1/2 period: Telemetry period for MCU devices.
- PWM ID: PWM ID associated to the Scorpion Tribunus.
The serial port has to be configured in the I/O Setup section.
An example of this can be seen in the Scorpion tribunus - Integration examples
Note
The serial port will be totally reserved for this, so it will not be usable to other things and the I/O Setup affecting it wil be ignored.